Photoelectric Smoke Alarm AK-218A

EN14604-compliant photoelectric smoke alarm with 10-year lithium battery. Response time <30 seconds, 40m² coverage. Suitable for residential, commercial, and warehouse environments.

Detail

Specifications

Overview

Photoelectric smoke detector operating on the light-scattering principle. Unique structural design and optical signal processing provide dust resistance, insect resistance, and immunity to ambient light interference — ensuring long-term stable operation. Responds well to both slow smouldering and open-flame smoke. Suitable for homes, shopping centres, hotels, warehouses, and other indoor environments.

Specifications

Parameter Value
Model AK-218A
Power supply DC 9V / 1200mAh lithium battery (10-year lifespan)
Operating current Standby <10 μA, Alarm <25 mA
Alarm output Audible/visual alarm, normally open signal (COM/NO)
Alarm indicator Red LED flash + buzzer
Buzzer volume 85 dB (at 10 ft)
Response time <30 s
Coverage area 40 m²
Operating conditions -20–70°C, Humidity 10%–90% (non-condensing)
Low battery alert Chirps every 40 seconds
Dimensions Φ126mm × 34mm
Housing material ABS
Weight 144 g
Standard EN14604:2005/AC:2008

Installation

  1. Mark two fixing holes on ceiling or wall using the bracket as a template; insert plastic anchors and mount the bracket firmly
  2. Insert battery into the rear compartment; rotate the alarm clockwise until it clicks into place
  3. After installation, the LED flashes approximately once per minute to indicate normal operation

Testing: Hold the test button for at least 3 seconds — a clear pulsed alarm tone indicates normal function.

Installation Guidelines

  • Avoid locations near doors, windows, or fans where air moves quickly
  • Do not install in bathrooms or other high-humidity / high-temperature areas
  • Keep a 0.5m clear space around the detector
  • Minimum 1.5m horizontal distance from air conditioning vents; minimum 0.5m from walls and beams
  • Install horizontally; maximum tilt angle 45°
  • Conduct a simulated fire test every six months

Maintenance

Clean with a soft brush every six months. If the test button produces no sound or smoke testing fails, check the power supply or contact us for service.